3000 Flow Conditioners
Westfall Model 3000 Flow ConditionerPatent Pending

Computer model of 3000 flow conditioning.
.579
Westfall developed the Model 3000 Flow Conditioner in response to a customer’s request for a conditioner to use in situations where measurement accuracy and low headloss were of utmost importance. The unique design straightens out the flow over a short distance and creates the fully developed velocity profile necessary for accurate measurement, with minimal headloss. It is particularly effective in situations where there are pipe bends creating swirl and turbulence.
Pressure loss versus flow rate of the Westfall 3000 compared to other devices.Download the Alden Lab’s test results.
Download the 3000 Flow Conditioner Catalog.
Features:
- Creates ideal conditions for accurate flow measurement, reducing flow meter error
- Provides fully developed velocity profile within 8 diameters
- Creates minimal headloss — 2/3 less than other conditioners
- Eliminates swirl induced by out-of-plane pipe bends
- Minimizes turbulence regardless of flow conditions or mal-distribution upstream
- Saves space with short installed length
- Can be fabricated from PVC, FRP, 316 Stainless Steel, with or without Teflon coating, and any other engineering materials to meet industry needs.
- Available in pipe diameters from 1/2” to 120”
- Low cost, easy installation
- Long service life and low maintenance requirements
Applications
- Municipal and industrial water treatment
- Potable water
- Waste water plants
Alden Research Laboratory, Inc. performed numerical simulations using the CFD software package FLUENT V6.3.26, a state-of-the-art, and finite volume-based fluid flow simulation package, to calculate the three-dimensional, incompressible, turbulent flow through the pipe and around the mixer.
They simulated a 1000-cfm air flow in a 6-in Sch40. steel pipe, after two out-of-plane 90° bends. The flow conditioner is installed 4D downstream of the second bend.
Alden Labs simulation of Westfall’s Model 3000
Air flow in a 6-in Sch40. steel pipe, after two out-of-plane 90° bends
Contours of Tangential Velocity (ft/s) for distances 2-10 D downstream of the flow conditioner inlet: Top - No mixer; Bottom - Mixer installed