Alden Reports
Computational Flow Model of 3050 Mixer[file size 720.7units_k]
Computational flow model of Westfall's 36" 3050 Three Stage mixer to be installed in the Perchlorate Blending Station for the city of Redlands, California.
Computational Flow Model of 2800 Mixer[file size 1.1units_m]
Computational flow model of Westfall's 40" 2800 mixer to be installed in the Hydrogen Sulfide Removal Facility in Litha, Florida for Tampa Bay Water.
Computational Flow Model of Westfall's 4000 Open Channel Mixer[file size 907.4units_k]
Computational flow model of Westfall's 4000 open channel mixer.
Computational Flow Model of Westfall's 3050 Staged Mixer AGM-10-R-17[file size 1.2units_m]
Computational flow model of Westfall's 3050 staged mixer with one, two and three sets of mixing tabs. Complete report.
Westfall 3050 Staged Mixer CFD Test Results[file size 98.0units_k]
Model 3050 Low Headloss static mixer CoV values as determined for single, double and triple rows of mixing tabs. Diagrams and charts.
Computational Flow Model of Westfall's 36-in. Model 3050 Leading Tab Low-head Mixer AGM-09-R-08[file size 655.6units_k]
Computational flow model of Westfall's 36" Model 3050 leading tab mixer. Compete report.
Computational Flow Model of Westfall's 3000 Leading Tab Flow Conditioner AGM-09-R-08 Rev.B[file size 1.6units_m]
Computational flow model of Westfall's leading tab flow conditioner Model 3000. Discussion of characteristics and performance regarding mitigation of swirling flow and development of fully developed profile. Complete report.
Mixing Tests for a 6" Westfall Model 2900 Variable Mixer[file size 1.8units_m]
Mixing tests of a 6" static mixer assembly comprised of a 0.9 beta mixer plate and an adjustable 0.7 beta mixer plate to determine mixing effectiveness and overall head loss. Complete report.
Flow Testing of Westfall 2900 Variable Mixers[file size 1.8units_m]
Mixing tests of a 6" static mixer assembly comprised of a 0.9 beta mixer plate and an adjustable 0.7 beta mixer plate to determine unrecoverable head loss. Complete report.
Mixing Tests of Westfall Model 2800 Static Mixer— 6" Diameter[file size 3.8units_m]
Test of the mixing effectiveness tested via dye injection sampling and overall head loss was measured with pressure tap system. Flow was measured by the gravimetric method. Complete report.
2800 and 3050 Cavitation Analysis[file size 97.2units_k]
2800 0.8-Beta Structural Analysis[file size 319.9units_k]